Download JNTUA B.Tech 4-2 R13 2017 April Regular 13A01804 Advanced Structural Engineering Question Paper

Download JNTUA (JNTU Anantapur) B.Tech R13 (Bachelor of Technology) 4th Year 2nd Semester 2017 April Regular 13A01804 Advanced Structural Engineering Previous Question Paper || Download B-Tech 4th Year 2nd Sem 13A01804 Advanced Structural Engineering Question Paper || JNTU Anantapur B.Tech 4-2 Previous Question Paper || JNTU Anantapur B.Tech ME 4-2 Previous Question Paper || JNTU Anantapur B.Tech CSE 4-2 Previous Question Paper || JNTU Anantapur B.Tech Mech 4-2 Previous Question Paper || JNTU Anantapur B.Tech EEE 4-2 Previous Question Paper || JNTU Anantapur B.Tech ECE 4-2 Previous Question Paper


Code: 13A01804

B.Tech IV Year II Semester (R13) Regular Examinations April 2017
ADVANCED STRUCTURAL ENGINEERING
(Civil Engineering)

Time: 3 hours Max. Marks: 70

Answer all questions
All questions carry equal marks

*****
1 Design an interior panel of a flat slab floor system for a warehouse 24 m x 24 m divided into
panels of 6 m x 6 m for a live load of 5 kN/m
2
. Use M25 grade concrete and Fe415 steel
respectively. Draw the reinforcement details.
OR
2 Design a circular cylindrical bunker of capacity 400 kN to store coal using M20 concrete and
Fe415 steel. Angle of repose , unit weight of coal 8 kN/m
3
. Coefficient of friction between coal
and concrete is 0.444. Draw plan and cross sectional elevation of the bunker showing the
reinforcement details.

3 A cylindrical tank of capacity 7,00,000 liters is resting on good unyielding ground. The depth of
tank is limited to 5 m. A free board of 300 mm may be provided. The wall and the base slab are
cast integrally. Design the tank using M20 concrete and Fe415 grade steel. Draw plan and cross
sectional elevation of the tank showing the reinforcement details
OR
4 A counterfort-type retaining wall is to be designed to support a soil embankment with sloping
discharge. Height of fill retained by wall = 9 m, surcharge angle = 10?, density of soil 16 kN/m
3
,
angle of internal friction , coefficient of friction between soil and base slab = 0.5, SBC of soil
= 200 kN/m
2
. Use M20 grade concrete and Fe415 grade HYSD bars. Design the counterfort type
retaining wall and sketch the reinforcement details in the wall.

*****