Download PTU M.Tech. EE 1st Semester 75215 POWER SYSTEM ANALYSIS Question Paper

Download PTU. I.K. Gujral Punjab Technical University (IKGPTU) M.Tech. EE 1st Semester 75215 POWER SYSTEM ANALYSIS Question Paper.

This post was last modified on 13 December 2019

PTU M.Tech 1st Semester Last 10 Years 2010-2020 Previous Question Papers|| Punjab Technical University


Roll No.

Total No. of Questions : 08

Total No. of Pages : 02

--- Content provided by​ FirstRanker.com ---

M.Tech. (EE) (2018 Batch) (Sem.-1)

POWER SYSTEM ANALYSIS

Subject Code : MTEE-101-18

M.Code: 75215

Time: 3 Hrs.

--- Content provided by‍ FirstRanker.com ---

Max. Marks : 60

INSTRUCTIONS TO CANDIDATES :

  1. Attempt any FIVE questions out of EIGHT questions.
  2. Each question carries TWELVE marks.
  1. a) Explain sparsity technique and optimal ordering. (4)

    --- Content provided by‍ FirstRanker.com ---

    b) The following is the system data for a load flow solution. The line admittances :

    Bus Code Admittance
    1-2 2-j8
    1-3 1-j4
    2-3 0.666-j2.664
    2-4 1-j4
    3-4 2-j8

    The schedule of active and reactive powers :

    --- Content provided by​ FirstRanker.com ---

    Bus Code P Q V Remarks
    1 - - 1.06 Slack
    2 0.5 0.2 1+j0 PQ
    3 0.4 0.3 1+j0 PQ
    4 0.3 0.1 1+j0 PQ
    Determine the voltages at the end of first iteration using Gauss-Seidal method. Take a =1.6. (8)
    FirstRanker.com
  2. a) With the help of a neat flow chart, explain the Newton-Raphson method of load flow solution when the system contains voltage-controlled buses in addition to swing bus and load bus. (8)
    b) Compare G-S method and N-R method of load flow solutions. (4)
  3. Discuss symmetrical component analysis of unsymmetrical faults. How is fault computation done using Z bus formulation? (12)
  4. --- Content provided by⁠ FirstRanker.com ---

  5. a) Derive the expression for the fault current and terminal voltage for a line to line fault occurs at the terminal of an unloaded 3-phase alternator. Assume that the alternator has an isolated neutral. (6)
    b) A 30 MVA, 11kV generator has Z1 = Z2 = j0.2 pu, Zo = j0.05 pu. A line to ground fault occurs on the generator terminals. Find the fault current and line to line voltages during the fault conditions. Assume that the generator neutral is solidly grounded. (6)
  6. Write short notes on :
    a) State estimation of power systems. (6)
    b) State estimation of the line power flow. (6)
  7. --- Content provided by‌ FirstRanker.com ---

  8. Discuss contingency analysis for power system using Brown's Method. (12)
  9. a) What is voltage collapse? Explain its causes and prevention methods taken against it. (6)
    b) Draw PV graph for a typical line. What is the use of this graph in voltage stability studies? (6)
  10. a) Give a flow chart for a load flow study on a power system using Fast Decoupled load flow method. (8)
    b) Explain why N-R method is preferred to G-S method for load flow studies in power system. (4)