Download GTU BE/B.Tech 2019 Winter 7th Sem New 2173515 Design Of Air Pollution Control System And Air Quality Modeling Question Paper

Download GTU (Gujarat Technological University) BE/BTech (Bachelor of Engineering / Bachelor of Technology) 2019 Winter 7th Sem New 2173515 Design Of Air Pollution Control System And Air Quality Modeling Previous Question Paper

1
Seat No.: ________ Enrolment No.___________

GUJARAT TECHNOLOGICAL UNIVERSITY

BE - SEMESTER ? VII (New) EXAMINATION ? WINTER 2019
Subject Code: 2173515 Date: 03/12/2019

Subject Name: Design Of Air Pollution Control System And Air Quality
Modeling
Time: 10:30 AM TO 01:00 PM Total Marks: 70

Instructions:

1. Attempt all questions.

2. Make suitable assumptions wherever necessary.

3. Figures to the right indicate full marks.


MARKS

Q.1 (a) Explain various natural mechanisms for removal of gaseous
component and particulate matter.
03
(b) Enlist different methods for prevention of air pollution problem. 04
(c) An aerosol consisting of particles 0.63 and 0.83 mm in diameter
in equal mass amounts passes through a gravity settler at a flow
rate of 3.60 L/min. Given the following data, use Stokes? law with
the Cunningham correction factor to calculate the efficiency of the
settler.
Length = 50 cm, Width = 20 cm, Height of channel = 0.124 cm,
Number of channels = 19
?= 1.05 g/cm3
? = 0.1 ? m
?= 0.0182 cp.
07

Q.2 (a) Write a note on Seaboard process, Girbotol process, Claus process
for sulphur removal during combustion.
03
(b) Write a note on Particle charging, Particle Collection and Removal
of collected dust in Electrostatic Precipitator.
04
(c) A cyclone on a cement plant suddenly malfunctions. By the time
the plant shuts down, some dust has accumulated on parked cars
and other buildings in the plant complex. The nearest affected area
is 700 ft from the cyclone location, and the furthest affected area
measurable on plant grounds is 2500 ft from the cyclone. What is
the particle size range of the dust that has landed on plant grounds?
On this day, the cyclone was discharging into a 6.0 mph wind. The
specific gravity of the cement is 1.96. The cyclone is located 175 ft
above the ground. Neglect effects of turbulence.
A diagram representing the system is provided. (S=smaller particle,
L= larger particle). For air at ambient conditions, one obtains
?= 0:0741 lb/ ft3
?= 1:23* 10
5
ft / s
Wind speed =o.6*5280= 31,700 ft/hr

07
OR
(c) Explain lime scrubbing process and magnesium oxide scrubbing
process for Sulphur removal from flue gases.
07
FirstRanker.com - FirstRanker's Choice
1
Seat No.: ________ Enrolment No.___________

GUJARAT TECHNOLOGICAL UNIVERSITY

BE - SEMESTER ? VII (New) EXAMINATION ? WINTER 2019
Subject Code: 2173515 Date: 03/12/2019

Subject Name: Design Of Air Pollution Control System And Air Quality
Modeling
Time: 10:30 AM TO 01:00 PM Total Marks: 70

Instructions:

1. Attempt all questions.

2. Make suitable assumptions wherever necessary.

3. Figures to the right indicate full marks.


MARKS

Q.1 (a) Explain various natural mechanisms for removal of gaseous
component and particulate matter.
03
(b) Enlist different methods for prevention of air pollution problem. 04
(c) An aerosol consisting of particles 0.63 and 0.83 mm in diameter
in equal mass amounts passes through a gravity settler at a flow
rate of 3.60 L/min. Given the following data, use Stokes? law with
the Cunningham correction factor to calculate the efficiency of the
settler.
Length = 50 cm, Width = 20 cm, Height of channel = 0.124 cm,
Number of channels = 19
?= 1.05 g/cm3
? = 0.1 ? m
?= 0.0182 cp.
07

Q.2 (a) Write a note on Seaboard process, Girbotol process, Claus process
for sulphur removal during combustion.
03
(b) Write a note on Particle charging, Particle Collection and Removal
of collected dust in Electrostatic Precipitator.
04
(c) A cyclone on a cement plant suddenly malfunctions. By the time
the plant shuts down, some dust has accumulated on parked cars
and other buildings in the plant complex. The nearest affected area
is 700 ft from the cyclone location, and the furthest affected area
measurable on plant grounds is 2500 ft from the cyclone. What is
the particle size range of the dust that has landed on plant grounds?
On this day, the cyclone was discharging into a 6.0 mph wind. The
specific gravity of the cement is 1.96. The cyclone is located 175 ft
above the ground. Neglect effects of turbulence.
A diagram representing the system is provided. (S=smaller particle,
L= larger particle). For air at ambient conditions, one obtains
?= 0:0741 lb/ ft3
?= 1:23* 10
5
ft / s
Wind speed =o.6*5280= 31,700 ft/hr

07
OR
(c) Explain lime scrubbing process and magnesium oxide scrubbing
process for Sulphur removal from flue gases.
07
2
Q.3 (a) Enlist most important methods on Sulphur reduction within
combustion chamber.
03
(b) Enlist methods of desulphurization of flue gases. 04
(c) A sodium hydroxide spray in air at 308C is to be collected in a
gravity settler. The unit is 30 ft wide, 15 ft high, and 40 ft long. The
volumetric flow rate of the gas is 42 ft3/s. Calculate the smallest
mist droplet (spherical in shape) that will be entirely collected by
the settler. The specific gravity of the mist droplets may be assumed
to be equal to 1.21.
07
OR
Q.3 (a) Write a note on Lapple theory. 03
(b) Write a note on Leith and Licht theory. 04
(c) Write all design equations of Electrostatic Precipitator and explain
their significance.
07
Q.4 (a) Enlist different methods for prevention of air pollution problem. 03
(b) Draw a chart for classification of gravity settler. 04
(c) Write a note on Simple Expansion Chamber. 07
OR
Q.4 (a) How many type of air cyclones are there? Explain briefly each type. 03
(b) Explain Desulphurization of flue gas by metal oxide. 04
(c) Write a note on activated carbon process for desulphurization of
flue gas.
07
Q.5 (a) Write a note on Particle charging, Particle Collection and Removal
of collected dust in Electrostatic Precipitator.
03
(b) If the temperature in Problem S1 is 258C, what is the smallest
droplet that can be controlled if the gas is at 2008C? Assume that
at 2008C,m ? 2.0 _ 1024 g/cm . s.
04
(c) Write a note on Multiple Trays settling Chamber. 07
OR

Q.5 (a) Derive performance equation (Design Equation) for gravity settling
chamber.
03
(b) Write all design equations of cyclone separator and explain their
significance.
04
(c) Enlist most important methods on Sulphur reduction within
combustion chamber.
07

*************

FirstRanker.com - FirstRanker's Choice

This post was last modified on 20 February 2020