Download PTU B.Tech 2020 March EE 7th and 8th Sem Power System Operation And Control Question Paper

Download PTU (I.K. Gujral Punjab Technical University Jalandhar (IKGPTU) ) BE/BTech EE (Electrical Engineering) 2020 March 7th and 8th Sem Power System Operation And Control Previous Question Paper

1 | M - 7 1 9 3 6 ( S 2 ) - 9 2 2
Roll No. Total No. of Pages : 02
Total No. of Questions : 09
B.Tech.(EE) (2012 Onwards E-II) (Sem.?7,8)
POWER SYSTEM OPERATION AND CONTROL
Subject Code : BTEE-804A
M.Code : 71936
Time : 3 Hrs. Max. Marks : 60
INSTRUCTION TO CANDIDATES :
1. SECTION-A is COMPULSORY consisting of TEN questions carrying TWO marks
each.
2. SECTION-B contains FIVE questions carrying FIVE marks each and students
have to attempt any FOUR questions.
3. SECTION-C contains THREE questions carrying TEN marks each and students
have to attempt any TWO questions.

SECTION-A
1. Answer briefly :
a. Define per unit droop.
b. What decides the loading of generating stations?
c. Give two conditions for proper synchronizing of alternators.
d. What is the function of load frequency control?
e. Define Spinning Reserve.
f. What are the advantages and disadvantages of synchronous compensators?
g. What is the purpose of primary ALFC?
h. Write the condition for the optimal power dispatch in a lossless system.
i. Define area control error.
j. Define state estimation.

FirstRanker.com - FirstRanker's Choice
1 | M - 7 1 9 3 6 ( S 2 ) - 9 2 2
Roll No. Total No. of Pages : 02
Total No. of Questions : 09
B.Tech.(EE) (2012 Onwards E-II) (Sem.?7,8)
POWER SYSTEM OPERATION AND CONTROL
Subject Code : BTEE-804A
M.Code : 71936
Time : 3 Hrs. Max. Marks : 60
INSTRUCTION TO CANDIDATES :
1. SECTION-A is COMPULSORY consisting of TEN questions carrying TWO marks
each.
2. SECTION-B contains FIVE questions carrying FIVE marks each and students
have to attempt any FOUR questions.
3. SECTION-C contains THREE questions carrying TEN marks each and students
have to attempt any TWO questions.

SECTION-A
1. Answer briefly :
a. Define per unit droop.
b. What decides the loading of generating stations?
c. Give two conditions for proper synchronizing of alternators.
d. What is the function of load frequency control?
e. Define Spinning Reserve.
f. What are the advantages and disadvantages of synchronous compensators?
g. What is the purpose of primary ALFC?
h. Write the condition for the optimal power dispatch in a lossless system.
i. Define area control error.
j. Define state estimation.

2 | M - 7 1 9 3 6 ( S 2 ) - 9 2 2
SECTION-B
2. Describe the automatic excitation control (IEEE Type 1) for alternators.
3. Describe the modelling of Modelling for contingency analysis.
4. Describe the turbine and speed governing systems.
5. Discuss the voltage stability of power system. What are the suitable effective counter
measures to prevent voltage instability?
6. Derive the necessary formula for active power scheduling taking into effect of
transmission loss and also derive the exact and approximate expressions for penalty
factor.

SECTION-C
7. Use the method of Lagrangian multiplier to derive the operating criteria for a large
number of units.
8. Derive the suitable mathematical formulation for voltage stability of a two bus radial
systems and correlate it with the PV curve for different values of power factor and QV
characteristics for different Values of P/Pmax.
9. Consider a steam station with two units having input output characteristics as follows :
F
1
=80 + 8P
1
+0.024P
1
2

F
2
=120+6P
2
+0.040P
2
2

where F represents the production cost.
In scheduling a load of 100 MW by equal incremental cost method, the incremental
production cost of unit 1 is wrongly specified by 10% more than the true value while that
of unit 2 is specified by 6% less than the true value. Find the following :
a. The change in generation schedule and
b. the change in the total cost of generation.


NOTE : Disclosure of Identity by writing Mobile No. or Making of passing request on any
page of Answer Sheet will lead to UMC against the Student.
FirstRanker.com - FirstRanker's Choice

This post was last modified on 21 March 2020