Roll No. EEEEEEEEEEE Total No. of Pages : 02
Total No. of Questions : 09
--- Content provided by FirstRanker.com ---
B.Tech.(EE) (2012 Onwards E-Il) (Sem.-7,8)
POWER SYSTEM OPERATION AND CONTROL
Subject Code : BTEE-804A
M.Code : 71936
Time : 3 Hrs. Max. Marks : 60
--- Content provided by FirstRanker.com ---
INSTRUCTION TO CANDIDATES :
- SECTION-A is COMPULSORY consisting of TEN questions carrying TWO marks each.
- SECTION-B contains FIVE questions carrying FIVE marks each and students have to attempt any FOUR questions.
- SECTION-C contains THREE questions carrying TEN marks each and students have to attempt any TWO questions.
SECTION-A
--- Content provided by FirstRanker.com ---
- Answer briefly :
- Define per unit droop.
- What decides the loading of generating stations?
- Give two conditions for proper synchronizing of alternators.
- What is the function of load-frequency control?
- Define Spinning Reserve.
- What are the advantages and disadvantages of synchronous compensators?
- What is the purpose of primary ALFC?
- Write the condition for the optimal power dispatch in a lossless system.
- Define area control error.
- Define state estimation.
--- Content provided by FirstRanker.com ---
--- Content provided by FirstRanker.com ---
SECTION-B
- Describe the automatic excitation control (IEEE Type 1) for alternators.
- Describe the modelling for contingency analysis.
- Describe the turbine and speed governing systems.
- Discuss the voltage stability of power system. What are the suitable effective counter measures to prevent voltage instability?
- Derive the necessary formula for active power scheduling taking into effect of transmission loss and also derive the exact and approximate expressions for penalty factor.
--- Content provided by FirstRanker.com ---
SECTION-C
- Use the method of Lagrangian multiplier to derive the operating criteria for a large number of units.
- Derive the suitable mathematical formulation for voltage stability of a two bus radial systems and correlate it with the PV curve for different values of power factor and QV characteristics for different Values of P/Pmax.
- Consider a steam station with two units having input output characteristics as follows :
F1 =80 + 8P1+0.024P12
F2=120+6P2+0.040P22
where F represents the production cost.--- Content provided by FirstRanker.com ---
In scheduling a load of 100 MW by equal incremental cost method, the incremental production cost of unit 1 is wrongly specified by 10% more than the true value while that of unit 2 is specified by 6% less than the true value. Find the following :- The change in generation schedule and
- the change in the total cost of generation.
--- Content provided by FirstRanker.com ---
NOTE : Disclosure of Identity by writing Mobile No. or Making of passing request on any page of Answer Sheet will lead to UMC against the Student.
--- Content provided by FirstRanker.com ---
This download link is referred from the post: PTU B.Tech Question Papers 2020 March (All Branches)
--- Content provided by FirstRanker.com ---