Download JNTUK M-Tech 2020 R19 EEE Advanced Power System Operation and Control Model Question Paper

Download JNTUK (Jawaharlal Nehru Technological University Kakinada (JNTU kakinada)) M.Tech (ME is Master of Engineering) 2020 R19 EEE Advanced Power System Operation and Control Model Previous Question Paper

[M19 PS 1101]

I M. Tech I Semester (R19) Regular Examinations
ADVANCED POWER SYSTEM OPERATION AND CONTROL
Electrical & Electronics Engineering Department
MODEL QUESTION PAPER
TIME: 3Hrs. Max. Marks: 75 M
Answer ONE Question from EACH UNIT.
All questions carry equal marks.
*****
C
O
KL M
UNIT-I
1. a). Explain the gradient approaches hydro-thermal scheduling. ? 2 K2 7M
b). Discuss the base point & participation factors method of
economic dispatch.
2 K2 8M
OR
2. a). Derive the composite generation protection cost function? 1 K2 7M
b). Explain how the fuel scheduling is done by linear
programming?
2 K2

8M

UNIT-II
3. a). Obtain the solution of an optimal unit commitment problem
with dynamic programming method?
3 K2 8M
b). Write the advantages of dynamic programming method over
priority list scheme?
3 K2 7M
OR
4. a). What are the varis constraints in unit commitment
problem? Explain them
3 K2 7M
b). Obtain the economic schedule for the two units, the
production costs of which are given follows to supply a load
of 3MW, in steps of 1MW.
C
1
=0.8 P
1
+25P
1
; C
2
= 1.2P
2
+22P
2
use dynamic programming
method.
3 K3 8M

UNIT-III
5. a). Describe the application of Optimal power flow 6 K2 7M
b). Explain the flow diagram of Security constrained OPF. 6 K2 8M
OR
6. a). Explain gradient method for optimal power flow 6 K2 7M
b). Discuss the strategy for solution of Linear Programming
optimal power flow problem with the help of flow diagram
6 K2 8M

UNIT-IV
7. a). Two generators of rating 100MW and 200MW are operated
with a droop characteristic of 6% from no load to full load.
Find the load shared by each generator, if a load of 270MW
is connected across the parallel combination of those
generators?
4 K3 7M
FirstRanker.com - FirstRanker's Choice
[M19 PS 1101]

I M. Tech I Semester (R19) Regular Examinations
ADVANCED POWER SYSTEM OPERATION AND CONTROL
Electrical & Electronics Engineering Department
MODEL QUESTION PAPER
TIME: 3Hrs. Max. Marks: 75 M
Answer ONE Question from EACH UNIT.
All questions carry equal marks.
*****
C
O
KL M
UNIT-I
1. a). Explain the gradient approaches hydro-thermal scheduling. ? 2 K2 7M
b). Discuss the base point & participation factors method of
economic dispatch.
2 K2 8M
OR
2. a). Derive the composite generation protection cost function? 1 K2 7M
b). Explain how the fuel scheduling is done by linear
programming?
2 K2

8M

UNIT-II
3. a). Obtain the solution of an optimal unit commitment problem
with dynamic programming method?
3 K2 8M
b). Write the advantages of dynamic programming method over
priority list scheme?
3 K2 7M
OR
4. a). What are the varis constraints in unit commitment
problem? Explain them
3 K2 7M
b). Obtain the economic schedule for the two units, the
production costs of which are given follows to supply a load
of 3MW, in steps of 1MW.
C
1
=0.8 P
1
+25P
1
; C
2
= 1.2P
2
+22P
2
use dynamic programming
method.
3 K3 8M

UNIT-III
5. a). Describe the application of Optimal power flow 6 K2 7M
b). Explain the flow diagram of Security constrained OPF. 6 K2 8M
OR
6. a). Explain gradient method for optimal power flow 6 K2 7M
b). Discuss the strategy for solution of Linear Programming
optimal power flow problem with the help of flow diagram
6 K2 8M

UNIT-IV
7. a). Two generators of rating 100MW and 200MW are operated
with a droop characteristic of 6% from no load to full load.
Find the load shared by each generator, if a load of 270MW
is connected across the parallel combination of those
generators?
4 K3 7M
b). Explain briefly abt modeling of single area load frequency
control with a neat sketch
4 K2 8M
OR
8. a). Explain the static response of two area system for un
controlled case?
4 K2 8M
b). Find the static frequency drop if the load is suddenly
increased by 25MW on a system having the following data:
Rated capacity is 500MW, operating load is 250MW, inertia
constant is 5s, governor regulation R= 2Hz/ p.u MW,
frequency is 50Hz. Also find the additional generation?
4 K3 6M

UNIT-V
9. a). Explain the concept of power pools with an example? 5 K2 7M
b). Explain abt the economy inter change evaluation with an
example?
5 K2 8M
OR
10. a). Discuss abt interchange evaluation with unit commitment 5 K2 7M
b). Explain the following i) Diversity interchange. ii)
Emergency power interchange
5 K2 8M





























FirstRanker.com - FirstRanker's Choice

This post was last modified on 28 April 2020