Q1
- Define Following:
- Under reach and over reach of relay
- Plug setting multiplier
- Burden
--- Content provided by FirstRanker.com ---
- Explain Following with reference to Circuit Breaker: (a) Breaking Current (b) Making Current 04 MARKS
- Discuss various zones of protection for a modern power system. Explain primary and back-up protection. 07 MARKS
Q2
--- Content provided by FirstRanker.com ---
- Explain in brief, how the percentage differential relay overcomes the drawbacks of simple differential relay. 03 MARKS
- What is power swing in power system? Evaluate performance of distance relay in case of a power swing. 04 MARKS
- A 10 MVA, 13.2 kv generator is protected by restricted earth fault protection. The relay is set to operate on 20% out of balance current. If 85% of the generator winding is supposed to be protected by the relay, find out value of resistance to be added in the neutral circuit. 07 MARKS
Q3
- Why does a generator needed to be tripped in the case of loss of excitation? 03 MARKS
- Explain following with respect to induction motor protection: (a) Single phasing (b) ground fault 04 MARKS
- Explain with neat diagram: construction and working of the numerical relay. 07 MARKS
--- Content provided by FirstRanker.com ---
Q4
- Explain why the first ground fault on the rotor does not cause any damage while a second fault can be catastrophic. 03 MARKS
- Explain following with respect to a circuit breaker:
- Resistance switching
- Arc chopping
--- Content provided by FirstRanker.com ---
- Draw and explain protection of generator against unbalanced loading. 07 MARKS
Q5
- Why can the secondary of a protection CT not to be open circuited? 03 MARKS
- Discuss the effects of arc resistance on impedance based protection scheme. 04 MARKS
- Drew and explain carrier current based transmission line protection scheme. 07 MARKS
--- Content provided by FirstRanker.com ---
Q.6
- What is the need of sample and hold circuit in a digital numeric relay? 03 MARKS
- What is single phasing in Induction motor? How protection against single phasing is provided? 04 MARKS
- Compare Impedance relay, reactance relay and mho/ offset mho relay for transmission line protection. 07 MARKS
--- Content provided by FirstRanker.com ---
Q.7
- Compose a suitable choice of circuit breakers for the following voltage ranges with appropriate reason. (a) 3.3kV to 33kV, (b) 400kV to 760kV. 03 MARKS
- List important protections provided in a 100MW generator and explain harmonic restrain relay. 04 MARKS
- In what manner the CTs are connected for biased differential protection of transformer having (i) delta-star connection. (ii) star-star connection. Give reason for the CT Connections employed. 07 MARKS
--- Content provided by FirstRanker.com ---
Q.8
- Give difference between measurement CT and protection CT. 03 MARKS
- Explain Restricted Earth Fault Protection for generator in detail. 04 MARKS
- Compare SF6 circuit breaker with Air blast circuit breaker. 07 MARKS