FirstRanker Logo

FirstRanker.com - FirstRanker's Choice is a hub of Question Papers & Study Materials for B-Tech, B.E, M-Tech, MCA, M.Sc, MBBS, BDS, MBA, B.Sc, Degree, B.Sc Nursing, B-Pharmacy, D-Pharmacy, MD, Medical, Dental, Engineering students. All services of FirstRanker.com are FREE

📱

Get the MBBS Question Bank Android App

Access previous years' papers, solved question papers, notes, and more on the go!

Install From Play Store

Download GTU B.Tech 2020 Winter 8th Sem 2180610 Design Of Steel Structures Question Paper

Download GTU (Gujarat Technological University Ahmedabad) B.Tech/BE (Bachelor of Technology/ Bachelor of Engineering) 2020 Winter 8th Sem 2180610 Design Of Steel Structures Previous Question Paper

This post was last modified on 04 March 2021

GTU B.Tech 2020 Winter Question Papers || Gujarat Technological University


FirstRanker.com

GUJARAT TECHNOLOGICAL UNIVERSITY

BE- SEMESTER-VIII (NEW) EXAMINATION — WINTER 2020

--- Content provided by‌ FirstRanker.com ---

Subject Code:2180610 Date:28/01/2021

Subject Name:Design of Steel Structures

Time:02:00 PM TO 04:00 PM Total Marks: 47

Instructions:

  1. Attempt any THREE questions from Q.1 to Q.6.
  2. --- Content provided by‍ FirstRanker.com ---

  3. Q7 is compulsory
  4. Make suitable assumptions wherever necessary.
  5. Figures to the right indicate full marks.
  6. Use of IS: 800, IS: 875 and Steel Tables is permitted, provided that they do not contain anything other than the printed matter inside.
  7. Consider fy = 250 N/mm? and fu = 410 N/mm? if not mention.
  8. --- Content provided by FirstRanker.com ---

MARKS

Q.1 (a) What are risk co-efficient, terrain factor and topography factor ? 03

(b) Write design consideration for heavy moment resisting bolted 04 connection.

(c) Determine the plastic moment capacity and plastic modulus of section of the 07 unsymmetric section shown in Fig 01.

Q.2 (a) Explain the analysis of roof column in Industrial building. 03

--- Content provided by⁠ FirstRanker.com ---

(b) Explain the failure of a riveted joint with suitable examples. 04

(c) The following data refers to a welded plate girder of span 24 m to carry 07 superimposed load of 35 kN/m. Avoid use of bearing and intermediate stiffeners. Use Fe 415 (E250) steel. find out

  1. Moment and shear force
  2. Depth of web plate.
  3. Selection of Flange.
  4. --- Content provided by​ FirstRanker.com ---

  5. Check for moment capacity of'the girder.
  6. Shear resistance of web.

Q.3 (a) Distinguish between elastic modulus and plastic modulus. 03

(b) Explain simple post critical method to evaluate shear strength of web of plate 04 girder as per IS 800:2007

(c) Using the following data calculate total W.L. on the truss. 07

--- Content provided by​ FirstRanker.com ---

  1. Total roof area = 72m?
  2. Risk factor K; & Topography factor K3 =1
  3. Terrain factor K
  4. Cpi==0.5
  5. Cpe=-0.8
  6. --- Content provided by‌ FirstRanker.com ---

  7. Place = Ahmedabad

Q.4 (a) Define: Rivet line, butt joint, Purlins. 03

(b) Enlist advantages and disadvantages of steel structures. 04

(c) Using the following data calculate wind load per panel point of a roof truss. 07

  1. Place = Indore
  2. --- Content provided by‌ FirstRanker.com ---

  3. Type of truss = Fink truss with slope equal to 26°.
  4. No. of panels on each sloping side = 4
  5. Opening of wall area = 16%
  6. Probable life of structure = 50 years.
  7. Topography factor = 1.00
  8. --- Content provided by FirstRanker.com ---

  9. Total slope area= 68 m%,h/w =0.75, Height =15 m.

Q.5 (a) Explain Lateral load due to Wind and Seismic as per L.S. Standard. 03

(b) Write various types of truss girder. 04

(c) Design the welded connection to connect two plates of width 200 mm and 07 thickness 10 mm for 100 percent efficiency.

Q.6 (a) What you understand by class 4.6 and class 8.8 bolts? Explain briefly 03

--- Content provided by​ FirstRanker.com ---

(b) Explain the following connections with neat sketches: beam to beam web 04 angle connection, beam to column flange seat angle connection

(c) Find the efficiency of the lap joint shown in Fig 02 Given M20 bolts and 07 grade 4.6 and Fe 410 (E 250) plates are used.

Q.7 (a) Explain effect of wind load on structure. 05

OR

Q.7 (a) Derive the collapse load for fixed beam of length L, subjected to 05 concentrated load W at centre.

--- Content provided by⁠ FirstRanker.com ---

FirstRanker.com



This download link is referred from the post: GTU B.Tech 2020 Winter Question Papers || Gujarat Technological University

--- Content provided by⁠ FirstRanker.com ---