Roll No.
Total No. of Pages : 02
Total No. of Questions : 09
--- Content provided by FirstRanker.com ---
B.Tech.(EE) (Electrical & Electronics) (2011 Onwards)
B.Tech.(Electrical Engineering & Industrial Control) (2012 Onwards)
(Sem.-6)
POWER SYSTEM-II
(Switch gear & Protection)
--- Content provided by FirstRanker.com ---
Subject Code : BTEE-602
M.Code : 71148
Time : 3 Hrs. Max. Marks : 60
INSTRUCTION TO CANDIDATES :
- SECTION-A is COMPULSORY consisting of TEN questions carrying TWO marks each.
- SECTION-B contains FIVE questions carrying FIVE marks each and students has to attempt any FOUR questions.
- SECTION-C contains THREE questions carrying TEN marks each and students has to attempt any TWO questions.
--- Content provided by FirstRanker.com ---
SECTION-A
- Answer briefly :
- Mention any two disadvantages of carrier current scheme for transmission line only.
- Why bus bar protection is needed?
- Explain the problem associated with the interruption of low inductive current.
- What is restriking and recovery voltage?
- Differentiate between a fuse and a circuit breaker.
- Why neutral resistor is added between neutral and earth of an alternator?
- What are the hazards imposed by oil when it is used as an arc quenching medium?
- Mention the various insulation levels in substations.
- Define Isolator and explain its requirements.
- Name the different types of bus bar arrangements in substations?
--- Content provided by FirstRanker.com ---
--- Content provided by FirstRanker.com ---
SECTION-B
--- Content provided by FirstRanker.com ---
- Explain with a neat sketch the working of biased differential Relay.
- Explain construction and working of HRC fuse.
- Explain any one bus bar arrangement used in substation in detail.
- Discuss and compare the various methods of neutral earthing.
- Describe the construction and working of Buchholz relay.
--- Content provided by FirstRanker.com ---
SECTION-C
-
- Explain basic distance protection scheme for protection of lines.
- Explain with a neat sketch construction and working of Stator Inter Turn Protection of alternators.
- Describe the operating principle, constructional features and area of applications of reverse power or directional relay.
-
- What protective measures are taken against lightning over voltages?
- Describe the construction and principle of operation of expulsion type lightning arrester.
--- Content provided by FirstRanker.com ---
NOTE : Disclosure of identity by writing mobile number or making passing request on any page of Answer sheet will lead to UMC against the Student.
--- Content provided by FirstRanker.com ---
This download link is referred from the post: PTU B.Tech 6th Semester Last 10 Years 2009-2019 Previous Question Papers|| Punjab Technical University
--- Content provided by FirstRanker.com ---