FirstRanker Logo

FirstRanker.com - FirstRanker's Choice is a hub of Question Papers & Study Materials for B-Tech, B.E, M-Tech, MCA, M.Sc, MBBS, BDS, MBA, B.Sc, Degree, B.Sc Nursing, B-Pharmacy, D-Pharmacy, MD, Medical, Dental, Engineering students. All services of FirstRanker.com are FREE

📱

Get the MBBS Question Bank Android App

Access previous years' papers, solved question papers, notes, and more on the go!

Install From Play Store

Download ARPIT 2019 Real Time Power System Analysis And Smart Grid Creation Question Paper

Download Annual Refresher Programme in Teaching (ARPIT) 2019 Real Time Power System Analysis And Smart Grid Creation Previous Question Paper || Annual Refresher Programme in Teaching (ARPIT) Last 10 Years Question Paper

This post was last modified on 19 January 2021

ARPIT Last 10 Years 2011-2021 Previous Question Papers


Question Paper Name: 5220 Real Time Power System Analysis and Smart Grid 30th June 2019 Shift 1

Subject Name: Real Time Power System Analysis and Smart Grid

Creation Date: 2019-06-30 13:01:46

--- Content provided by​ FirstRanker.com ---

Duration: 180

Total Marks: 100

Display Marks: Yes

Real Time Power System Analysis and Smart Grid

Group Number: 1

--- Content provided by FirstRanker.com ---

Group Id: 489994175

Group Maximum Duration: 0

Group Minimum Duration: 120

Revisit allowed for view?: No

Revisit allowed for edit?: No

--- Content provided by‍ FirstRanker.com ---

Break time: 0

Group Marks: 100

Real Time Power System Analysis and Smart Grid

Section Id: 489994231

Section Number: 1

--- Content provided by‍ FirstRanker.com ---

Section type: Online

Mandatory or Optional: Mandatory

Number of Questions: 100

Number of Questions to be attempted: 100

Section Marks: 100

--- Content provided by‍ FirstRanker.com ---

Display Number Panel: Yes

Group All Questions: No

Sub-Section Number: 1

Sub-Section Id: 489994248

Question Shuffling Allowed: Yes

--- Content provided by FirstRanker.com ---

Question Number: 1 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

In traditional power system, energy generally flows in

A. One direction

B. Bi-direction

--- Content provided by⁠ FirstRanker.com ---

C. Does not flow

D. None of the above

Options:

1. 1

2. 2

--- Content provided by​ FirstRanker.com ---

3. 3

Question Number: 2 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Equal area criterion gives the information regarding

A. stability region

--- Content provided by​ FirstRanker.com ---

B. absolute stability

C. relative stability

D. swing curves

Options:

1. 1

--- Content provided by FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 3 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by FirstRanker.com ---

Steady state stability of a power system is improved by

A. Single pole switching

B. Decreasing generator inertia

C. using double circuit line instead of single circuit line

D. all of the above

--- Content provided by⁠ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by⁠ FirstRanker.com ---

Question Number: 4 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

What is the value of transient stability limit?

A. Higher than steady state stability limit

B. Lower than steady state stability limit.

--- Content provided by‍ FirstRanker.com ---

C. Depending upon the severity of load

D. All of these

Options:

1. 1

2. 2

--- Content provided by⁠ FirstRanker.com ---

3. 3

4. 4

Question Number: 5 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

A. The maximum flow of power through a particular component connected in the power system

--- Content provided by‍ FirstRanker.com ---

Question Number: 6 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

What is power system stability?

A. The maximum power flow possible through a particular component connected in the power system.

B. The ability of the power system to regain the state of operating equilibrium point when the system is subjected to any disturbances.

--- Content provided by​ FirstRanker.com ---

C. It is a phenomenon in which a power system losses its operating equilibrium when subjected to large disturbances.

D. All of these

Options:

1. 1

2. 2

--- Content provided by‍ FirstRanker.com ---

3. 3

4. 4

Question Number: 7 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Advantages of gauss siedel method is/are

--- Content provided by⁠ FirstRanker.com ---

A. calculation time for each iteration is less

B. number of iterations are less

C. applicable for large power system network

D. all of the above

Options:

--- Content provided by FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 8 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by​ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

In load flow studies, the quantities specified at load bus are

A. P and V

B. P and Q

C. V and d

--- Content provided by⁠ FirstRanker.com ---

D. d and Q

Options:

1. 1

2. 2

3. 3

--- Content provided by‍ FirstRanker.com ---

4. 4

Question Number: 9 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Which of the following matrix is used for load flow studies?

A. Y bus matrix

--- Content provided by⁠ FirstRanker.com ---

B. Z bus matrix

C. Unit Matrix

D. Null Matrix

Options:

1. 1

--- Content provided by​ FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 10 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by‍ FirstRanker.com ---

In load flow studies PV bus is treated as PQ bus when

A. phase angle become high

B. voltage at the bus become high

C. reactive power goes beyond limit

D. any of the above

--- Content provided by‍ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by‌ FirstRanker.com ---

Question Number: 11 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

For accurate load flow calculations on large power systems, the best method is

A. N-R method

B. G-S method

--- Content provided by‍ FirstRanker.com ---

C. Decoupled method

D. All of the above

Options:

1. 1

2. 2

--- Content provided by‍ FirstRanker.com ---

3. 3

Question Number: 12 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

The Critical Clearance time of a fault in the power system is related to

A. Reactive power limit

--- Content provided by‌ FirstRanker.com ---

B. Short Circuit limit

C. Steady state stability limit

D. Transient stability limit

Options:

1. 1

--- Content provided by⁠ FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 13 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by​ FirstRanker.com ---

If the torque angle of the alternator increases indefinitely the system will show

A. Steady state stability limit

B. Transient state stability limit

C. Instability

D. None of the above

--- Content provided by​ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by FirstRanker.com ---

Question Number: 14 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

The steady state stability of the power system can be improved by:

A. Increasing the number of parallel lines between the transmission points

B. Connecting capacitors in series with the line

--- Content provided by‌ FirstRanker.com ---

C. Reducing the excitation of the machines

D. Both a and b

Options:

1. 1

2. 2

--- Content provided by‌ FirstRanker.com ---

3. 3

4. 4

Question Number: 15 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

speed breakers can

--- Content provided by​ FirstRanker.com ---

A. Increase the transient stability

B. Decrease the transient stability

C. Increase the steady state stability

D. Decrease the steady state stability

Options:

--- Content provided by⁠ FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 16 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by‌ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

In Hardware in loop

A. Both controller and plant are in simulation

B. Plant is simulated and controller is real

C. Controller is simulated and plant is real

--- Content provided by‍ FirstRanker.com ---

D. None of the above

Options:

1. 1

2. 2

3. 3

--- Content provided by⁠ FirstRanker.com ---

4. 4

Question Number: 17 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Real-time Simulation

A. Is required when real hardware is connected to the simulation

--- Content provided by‌ FirstRanker.com ---

B. ensures coherent time responses: determinism

C. allows the simulation to lure the real hardware

D. all of above

Options:

1. 1

--- Content provided by FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 18 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by FirstRanker.com ---

In real time simulation, which of the following solver is used:

A. Variable step

B. Fixed step

C. Both a and b

D. None of the above

--- Content provided by‌ FirstRanker.com ---

Options:

1. 1

2. 2

Question Number: 19 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by⁠ FirstRanker.com ---

In real time simulation, host PC and target PC are connected through

A. Ethernet

B. Wi-fi

C. Bluetooth

D. None of the above

--- Content provided by⁠ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by FirstRanker.com ---

Question Number: 20 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

In RT lab, following block is used for communication between two subsystems:

A. OpComm

B. Opwrite

--- Content provided by⁠ FirstRanker.com ---

C. Both a and b

D. None of the above

Options:

1. 1

2. 2

--- Content provided by‍ FirstRanker.com ---

3. 3

4. 4

Question Number: 21 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Syntax for Master subsystem in RTLab is:

--- Content provided by FirstRanker.com ---

A. SM

B. CM

C. ZM

D. GM

Options:

--- Content provided by⁠ FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 22 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by⁠ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

A.

B. CS

C. ZS

D. GS

--- Content provided by⁠ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by‌ FirstRanker.com ---

Question Number: 23 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Syntax for Console subsystem is

A. SC

B. CC

--- Content provided by FirstRanker.com ---

C. ZC

D. GC

Options:

1. 1

2. 2

--- Content provided by‍ FirstRanker.com ---

3. 3

4. 4

Question Number: 24 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Shunt Compensation is used to

--- Content provided by​ FirstRanker.com ---

A. Improve voltage Profile

B. Decrease Transmission line impedance

C. Control phase angle

D. None of these

Options:

--- Content provided by⁠ FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 25 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by​ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

Series Compensation is used to

A. Improve voltage Profile

B. Decrease Transmission line impedance

C. Control phase angle

--- Content provided by FirstRanker.com ---

D. Both B and C

Options:

1. 1

2. 2

3. 3

--- Content provided by FirstRanker.com ---

Question Number: 26 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

When voltage generated by STATCOM (Vo) exceeds system voltage (Vs),

A. Reactive power is generated by STATCOM

B. Reactive power is absorbed by STATCOM

--- Content provided by⁠ FirstRanker.com ---

C. Active power is generated by STATCOM

D. Active power is absorbed by STATCOM

Options:

1. 1

2. 2

--- Content provided by​ FirstRanker.com ---

3. 3

4. 4

Question Number: 27 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

When voltage generated by STATCOM (Vo) is less than system voltage (Vs),

--- Content provided by‍ FirstRanker.com ---

A. Reactive power is generated by STATCOM

B. Reactive power is absorbed by STATCOM

C. Active power is generated by STATCOM

D. Active power is absorbed by STATCOM

Options:

--- Content provided by⁠ FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 28 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by‌ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

When voltage generated by STATCOM (Vo) leads system voltage (Vs),

A. Reactive power is generated by STATCOM

B. Reactive power is absorbed by STATCOM

C. Active power is generated by STATCOM

--- Content provided by‌ FirstRanker.com ---

D. Active power is absorbed by STATCOM

Options:

1. 1

2. 2

3. 3

--- Content provided by‌ FirstRanker.com ---

4. 4

Question Number: 29 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

A. Reactive power is generated by STATCOM (Vo) lags system voltage (Vs),

Question Number: 30 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by‍ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

TCSC is used to

A. Reduce Transmission line impedance

B. Increase Transmission line impedance

C. Improve Voltage Profile of transmission line

--- Content provided by​ FirstRanker.com ---

D. None of the above

Options:

1. 1

2. 2

3. 3

--- Content provided by‌ FirstRanker.com ---

4. 4

Question Number: 31 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

TCSC can control the line impedance through the introduction of a

A. thyristor controlled capacitor in series with the transmission line

--- Content provided by‌ FirstRanker.com ---

B. thyristor controlled reactor in series with the transmission line

C. thyristor controlled capacitor in parallel with the transmission line

D. thyristor controlled reactor in parallel with the transmission line

Options:

1. 1

--- Content provided by⁠ FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 32 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by‌ FirstRanker.com ---

When the reactance of the fixed capacitor is less than that of the parallel connected variable reactor in TCSC,

A. this combination provides a variable capacitive reactance.

B. A resonance develops that result in infinite capacitive impedance,

C. combination provides a variable inductive reactance

D. None of the above

--- Content provided by‌ FirstRanker.com ---

Options:

1. 1

2. 2

Question Number: 33 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by⁠ FirstRanker.com ---

When the reactance of the fixed capacitor is equal to that of the parallel connected variable reactor in TCSC,

A. this combination provides a variable capacitive reactance.

B. A resonance develops that result in infinite capacitive impedance,

C. combination provides a variable inductive reactance

D. None of the above

--- Content provided by‌ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by‌ FirstRanker.com ---

Question Number: 34 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

When the reactance of the fixed capacitor is greater than that of the parallel connected variable reactor in TCSC,

A. his combination provides a variable capacitive reactance.

B. A resonance develops that result in infinite capacitive impedance,

--- Content provided by‍ FirstRanker.com ---

C. combination provides a variable inductive reactance

D. None of the above

Options:

1. 1

2. 2

--- Content provided by FirstRanker.com ---

3. 3

4. 4

Question Number: 35 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

UPFC is capable of regulating

--- Content provided by FirstRanker.com ---

A. Regulating voltage of bus

B. active power flow acting as a phase shifter

C. active power flow acting as a variable series compensator

D. All of the above

Options:

--- Content provided by​ FirstRanker.com ---

1. 1

2. 2

3. 3

4. 4

Question Number: 36 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by‌ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

se angle of series injected voltage is in phase with nodal voltage

A. UPFC regulates the voltage of bus

B. UPFC regulates active power flow acting as a phase shifter.

C. UPFC regulates active power flow acting as a variable series compensator.

--- Content provided by FirstRanker.com ---

D. UPFC operates as a combination of the voltage regulator, phase shifter, and variable series compensator.

Options:

1. 1

2. 2

3. 3

--- Content provided by‌ FirstRanker.com ---

4. 4

Question Number: 37 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

UPFC is capable of

A. Capable of controlling all power flow parameters (V, d, X) either simultaneously or selectively

--- Content provided by⁠ FirstRanker.com ---

B. Operated as SSSC, or STATCOM independently

C. independently control real power without altering reactive power

D. All of the above

Options:

1. 1

--- Content provided by‌ FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 38 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by‌ FirstRanker.com ---

Disadvantage(s) of UPFC is/are

A. Cost per KVAR is very high

B. Procurement, and installation of UPFC is an exclusive monopoly of the supplier

C. Both A and B

D. None of the above

--- Content provided by⁠ FirstRanker.com ---

Options:

1. 1

2. 2

3. 3

4. 4

--- Content provided by‌ FirstRanker.com ---

Question Number: 39 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

FDLF method is used for what studies?

A. Multiple load flow studies

B. Optimisation studies

--- Content provided by‍ FirstRanker.com ---

C. Small size systems

D. Both (a) and (b)

Options:

1. 1

Question Number: 40 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

--- Content provided by​ FirstRanker.com ---

Correct Marks: 1 Wrong Marks: 0

Transient stability limit of a power system be improved by using

A. Series inductor

B. Shunt resistance

C. Series Resistance

--- Content provided by FirstRanker.com ---

D. Series Capacitor

Options:

1. 1

2. 2

3. 3

--- Content provided by FirstRanker.com ---

4. 4

Question Number: 41 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

Transient stability limit is defined as

A. The maximum power flow possible through a particular component connected in the power system.

--- Content provided by⁠ FirstRanker.com ---

B. The maximum flow of power through a particular point in the power system without loss of stability when large and sudden disturbances occur.

C. The maximum flow of power through a particular point in the power system without loss of stability when small disturbances occur.

D. None of the above

Options:

1. 1

--- Content provided by‌ FirstRanker.com ---

2. 2

3. 3

4. 4

Question Number: 42 Question Type: MCQ Option Shuffling: No Display Question Number: Yes Single Line Question Option: No Option Orientation: Vertical

Correct Marks: 1 Wrong Marks: 0

--- Content provided by‌ FirstRanker.com ---

The main drawback in NR method is

A. A large memory allocation is required to store the jacobian matrix

B. The number of iterations is more

C. Slow to converge

D. All of these

--- Content provided by‍ FirstRanker.com ---

Options:

1. 1

2. 2

This download link is referred from the post: ARPIT Last 10 Years 2011-2021 Previous Question Papers

--- Content provided by‍ FirstRanker.com ---