FirstRanker Logo

FirstRanker.com - FirstRanker's Choice is a hub of Question Papers & Study Materials for B-Tech, B.E, M-Tech, MCA, M.Sc, MBBS, BDS, MBA, B.Sc, Degree, B.Sc Nursing, B-Pharmacy, D-Pharmacy, MD, Medical, Dental, Engineering students. All services of FirstRanker.com are FREE

📱

Get the MBBS Question Bank Android App

Access previous years' papers, solved question papers, notes, and more on the go!

Install From Play Store

Download PTU B.Tech 2021 Jan EE 9th Sem 75642 Power System Analysis Question Paper

Download PTU (Punjab Technical University) B.Tech (Bachelor of Technology) / BE (Bachelor of Engineering) 2021 January EE 9th Sem 75642 Power System Analysis Previous Question Paper

This post was last modified on 26 June 2021

This download link is referred from the post: PTU B.Tech 7th Semester Last 10 Years Previous Question Papers|| Punjab Technical University 2011-2021


FirstRanker's choice

FirstRanker.com

Total No. of Pages : 02

--- Content provided by FirstRanker.com ---

Roll No.

Total No. of Questions : 18

B.Tech. (EE) PT (Sem.-9)

POWER SYSTEM ANALYSIS

Subject Code : BTEE-801

--- Content provided by FirstRanker.com ---

M.Code: 75642

Time: 3 Hrs.

Max. Marks : 60

INSTRUCTIONS TO CANDIDATES :

  1. SECTION-A is COMPULSORY consisting of TEN questions carrying TWO marks each.
  2. --- Content provided by FirstRanker.com ---

  3. SECTION-B contains FIVE questions carrying FIVE marks each and students have to attempt any FOUR questions.
  4. SECTION-C contains THREE questions carrying TEN marks each and students have to attempt any TWO questions.

SECTION-A

Write briefly :

  1. What is meant by fault level?
  2. --- Content provided by FirstRanker.com ---

  3. What are the approximates in short circuit analysis?
  4. What are the current limiting reactors?
  5. Name the fault which do not have zero-sequence currents flowing.
  6. Draw the zero-sequence network for a star connected generator earthed through a resistance R.
  7. Write the general expression for complex power injected by the source into ith bus of a power system.
  8. --- Content provided by FirstRanker.com ---

  9. What is meant by acceleration factor in load flow solution and its best value?
  10. Define steady state stability.
  11. What is meant by power angle curve?
  12. Write swing equation for single machine system.

SECTION-B

--- Content provided by FirstRanker.com ---

  1. Explain the positive, negative and zero sequence components. Also mention its significance in Power System Analysis. Discuss the limitations of sequence components.
  2. A single phase transformer is rated 100kVA, 11/0.4 kV. Its leakage reactance is 0.15 Ω when referred to low voltage side. Determine its leakage reactance in percent and per unit.
  3. What are the causes of unsymmetrical faults in power system? Derive an expression for the fault current for a single line to ground fault.
  4. Discuss the advantages of using Ybus model of power system network for load flow analysis.
  5. A 100 MVA synchronous generator operates on full load at a frequency of 50 Hz. The load is suddenly reduced to 50 MW. Due to time lag in governor system, the steam valve begins to close after 0.4 second. Determine the change in frequency that occur in this time. Given H = 5 kW- s/kVA of generator capacity.
  6. --- Content provided by FirstRanker.com ---

SECTION-C

  1. A generator operating at 50 Hz. Delivers 1 pu power to an infinite bus when a fault occurs and reduces the maximum power transferable to 0.4 pu. The maximum power transferable before the occurrence of fault was 1.75 pu. The maximum power transferable after clearance of the fault is 1.25 pu. Compute critical clearing angle.
  2. Derive the load flow algorithm using Newton Raphson method with flow chart and discuss the advantages of the method.
  3. A 3phase star connected alternator is rated 30 MVA, 13.8 kV and has the following sequence reactance values: X₁ = 0.25 pu; X₂ = 0.35 pu; and X₀ = 0.10 pu. The neutral of the alternator is solidly grounded. Determine the alternator line currents when a double line to grounds fault occurs on its terminals. Assume that the alternator is unloaded and is operating at rated voltage when the fault occurs.

NOTE : Disclosure of Identity by writing Mobile No. or Making of passing request on any page of Answer Sheet will lead to UMC against the Student.

--- Content provided by FirstRanker.com ---



This download link is referred from the post: PTU B.Tech 7th Semester Last 10 Years Previous Question Papers|| Punjab Technical University 2011-2021

--- Content provided by FirstRanker.com ---