Q1. Make the suitable detail of counter for Rural Dispensary with seating in rural area of Rajasthan. 20
Q2. Design and Detail the show-window for the shop under the mezzanine located above the entrance of Jewelry Showroom (Clear height-3600mm). The total space allocated is 4500mmx4500mm in plan. 20
Q3. Make the 3 options for acoustic paneling to be used in auditorium. Wall thickness is 230mm with cement plaster on both the sides: Difference between the planes of acoustic wall and structural wall is 450mm. 20
--- Content provided by FirstRanker.com ---
Q4. Make the suitable details of expansion joint treatment using Masterflex and poly sulphide fille material injunctions of column-column, slab-slab and beam-beam. 20
Q5. Make the details of ventilation shaft for the triple basement showing cross section and Plan at each level. Floor-to floor height is 3600mm. Plinth level is 1850mm. Raft thickness is 900mm. Column size is 600x600mm. Beam Depth-450mm. Slab thickness is 150mm. 40