Roll No. Total No. of Pages : 01
Total No. of Questions : 06
B. Architecture (2012 & Onwards) (Sem.-8)
BUILDING CONSTRUCTION & MATERIALS-VII
Subject Code : BACH-802
--- Content provided by FirstRanker.com ---
M.Code : 72746
Time : 4 Hrs. Max. Marks : 75
INSTRUCTIONS TO CANDIDATES :
- Attempt 3 questions in all with at least one question from each unit.
- Assume any missing data/dimension. Assume suitable scale if not mentioned.
--- Content provided by FirstRanker.com ---
UNIT-I
Q1. Design and detail out a shop counter (8.5 M long) with all the relevant details along with specifications. 25
Q2. Design and draw suitable details for an 8 m long counter in a post office. 25
UNIT-II
Q3. Design and detail out false ceiling and wall panelling for an Architect's Office (size 6m x 5m), clearly showing provisions for lighting fixtures, AC diffuser etc. 25
--- Content provided by FirstRanker.com ---
Q4. Design and detail out false ceiling and wall panelling (with necessary acoustical treatment) for a conference hall of size 8m x 6m. 25
UNIT -111
Q5. a. Draw a detailed section from the basement wall of a building clearly showing all the necessary details of waterproofing treatment. 10
b. Differentiate between extension joint and expansion joint. Draw different types of expansion joints in brickwork, RCC framed structure (Columns, beams and slab) 15
Q6. What is prefabrication in building construction? Discuss prefabricated components along with their construction details. 25