Firstranker's choice
--- Content provided by FirstRanker.com ---
Roll No. Total No. of Pages : 02
Total No. of Questions : 01
B. Architecture (2012 & Onwards) (Sem.-5)
--- Content provided by FirstRanker.com ---
ARCHITECTURAL DESIGN-V
Subject Code : BACH-501
M.Code : 71745
Time : 12 Hrs.(Continue Next Day) Max. Marks : 100
INSTRUCTIONS TO CANDIDATES :
--- Content provided by FirstRanker.com ---
- At the end of the first day you are supposed to submit the design concept, and the Preliminary submission. You can retain a copy of the Preliminary submission for your final submission.
- No major deviation from the preliminary design is allowed in the final design.
- The appropriate area requirements have to be deduced by the students themselves if not mentioned.
- The students are free to add a suitable requirement with justification.
- Choose a suitable scale for your drawings.
- Assume any missing data and mention the same.
- Credit will be given for good drafting and rendering.
- Site Plan attached.
--- Content provided by FirstRanker.com ---
TOURIST CUM CONFERENCE CENTRE AT GOA
The Goa Tourism department is planning to develop a tourist cum conference centre at Baga beach, Goa. The site overlooks the Baga beach and is a prime property. The Design requirements are:
--- Content provided by FirstRanker.com ---
- Reception cum lounge with toilets, Managers office, and Tourist information centre with souvenir shop.
- 20 nos. double bed rooms with attached toilet and dress.
- 10 nos. dormitories (4 bedded each) with dressing and toilets.
- 20 cottages with double bedroom, sitting room, dress cum toilet, pantry and sit out - 40 sq m each.
- Restaurant for 100 persons, with kitchen, pantry and store.
- Conference room for 100 persons.
- Swimming pool with changing rooms, toilets for males and females and treatment plant etc.
- Parking for 50 cars and 5 buses.
--- Content provided by FirstRanker.com ---
--- Content provided by FirstRanker.com ---
Firstranker's choice
- Staff accommodation for 6 families (One multipurpose room, kitchen and one w.c. and one bath.
DRAWINGS REQUIRED.
End of First day
--- Content provided by FirstRanker.com ---
- Design Concept sheet.
- Preliminary Site Plan and Floor plans.(Drawn to scale)
End of Second day
- Final Site Plan.
- Final floor plans of the tourist cum conference centre, with one elevation and one section.
- Plan/s, one elevations and one Section each of cottage.
--- Content provided by FirstRanker.com ---
SITE FOR TOURIST CUM CONFERENCE CENTRE AT GOA
SITE PLAN (not to scale)
All dimensions in metres
--- Content provided by FirstRanker.com ---
NOTE : Disclosure of Identity by writing Mobile No. or Making of passing request on any page of Answer Sheet will lead to UMC against the Student.
--- Content provided by FirstRanker.com ---
This download link is referred from the post: PTU B-Arch 2019 May Previous Question Papers