FirstRanker Logo

FirstRanker.com - FirstRanker's Choice is a hub of Question Papers & Study Materials for B-Tech, B.E, M-Tech, MCA, M.Sc, MBBS, BDS, MBA, B.Sc, Degree, B.Sc Nursing, B-Pharmacy, D-Pharmacy, MD, Medical, Dental, Engineering students. All services of FirstRanker.com are FREE

📱

Get the MBBS Question Bank Android App

Access previous years' papers, solved question papers, notes, and more on the go!

Install From Play Store

Download GTU BE/B.Tech 2019 Winter 7th Sem New 2170908 Switch Gear And Protection Question Paper

Download GTU (Gujarat Technological University) BE/BTech (Bachelor of Engineering / Bachelor of Technology) 2019 Winter 7th Sem New 2170908 Switch Gear And Protection Previous Question Paper

This post was last modified on 20 February 2020

GTU BE/B.Tech 2019 Winter Question Papers || Gujarat Technological University


FirstRanker.com

GUJARAT TECHNOLOGICAL UNIVERSITY
BE - SEMESTER- VII (New) EXAMINATION — WINTER 2019

--- Content provided by‍ FirstRanker.com ---

Subject Code: 2170908 Date: 26/11/2019
Subject Name: Switch Gear and Protection
Time: 10:30 AM TO 01:00 PM Total Marks: 70

Instructions:

  1. Attempt all questions.
  2. --- Content provided by FirstRanker.com ---

  3. Make suitable assumptions wherever necessary.
  4. Figures to the right indicate full marks.

MARKS

Q.1 (a) With neat diagram explain the working of shaded pole type 03
electromagnetic induction disc relay.

--- Content provided by​ FirstRanker.com ---

(b) Classify the types of relays with respect to different category. 04

(c) Explain the following protection scheme as applied to synchronous 07
generator:
(a) Loss of excitation protection
(b) Stator inter-turn fault protection

--- Content provided by FirstRanker.com ---

Q.2 (a) Discuss the difficulties in implementing HVDC circuit breaker. 03

(b) Explain the behavior of Merz—Price protection during normal load, 04
external fault and internal fault condition.

(c) Compare the performance of distance relay in respect of its sensitivity to 07
following:

--- Content provided by‍ FirstRanker.com ---

(a) Effect of arc resistance,
(b) Effect of power swing
(c) Directional property

OR

(c) Select CT ratios and determine the TMS, and Plug setting of the IDMT 07

--- Content provided by​ FirstRanker.com ---

relays at location O and A, for the over-current protection of radial feeder
shown in Fig.1. The characteristic.of IDMT relay is given in the Table-2.
Minimum fault currents at each point are given Table-1. Maximum load
current from each bus are‘indicated in the Fig .

--- Content provided by FirstRanker.com ---

This download link is referred from the post: GTU BE/B.Tech 2019 Winter Question Papers || Gujarat Technological University